MPRX® 331 / MPRX® 331 FLEXISHIP® 0.6/1 (1.2) kV

Products

MPRX FLEXISHIP 331 0.6/1kV 1x35

Nexans ref. 10104147

  • Packaging: Cut to length (1000m)
  • Conductor flexibility: Stranded class 5
  • Number of cores: 1
  • Conductor cross-section: 35 mm²
  • Minimum outer diameter: 11.5 mm
  • Maximum outer diameter: 13.2 mm
  • Approximate weight: 390 kg/km
  • Permissible current rating in open air: 157 A

 

MPRX 331 0.6/1KV 3X1.5

Nexans ref. 10046204

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 9.0 mm
  • Maximum outer diameter: 11.5 mm
  • Approximate weight: 107 kg/km
  • Permissible current rating in open air: 16 A

 

MPRX 331 0.6/1kV 3x2.5

Nexans ref. 10046205

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 10.0 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 140 kg/km
  • Permissible current rating in open air: 21 A

 

MPRX 331 0.6/1kV 3x35

Nexans ref. 10045632

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 3
  • Conductor cross-section: 35 mm²
  • Minimum outer diameter: 23.0 mm
  • Maximum outer diameter: 26.0 mm
  • Approximate weight: 1460 kg/km
  • Permissible current rating in open air: 110 A

 

MPRX 331 0.6/1KV 3X70 SC

Nexans ref. 10045634

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Minimum outer diameter: 29.0 mm
  • Maximum outer diameter: 32.0 mm
  • Approximate weight: 2570 kg/km
  • Permissible current rating in open air: - A

 

MPRX 331 0.6/1kV 3x120 SC

Nexans ref. 10171196

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Minimum outer diameter: 35.0 mm
  • Maximum outer diameter: 39.0 mm
  • Approximate weight: 4180 kg/km
  • Permissible current rating in open air: - A

 

MPRX 331 0.6/1KV 4x1.5

Nexans ref. 10171710

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 10.0 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 131 kg/km
  • Permissible current rating in open air: 16 A

 

MPRX 331 0.6/1kV 4x2.5

Nexans ref. 10171728

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 11.0 mm
  • Maximum outer diameter: 13.5 mm
  • Approximate weight: 177 kg/km
  • Permissible current rating in open air: 21 A

 

MPRX 331 0.6/1kV 4x6

Nexans ref. 10171163

  • Packaging: Cut to length (m)
  • Conductor flexibility: Stranded class 2
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Minimum outer diameter: 13.5 mm
  • Maximum outer diameter: 16.0 mm
  • Approximate weight: 330 kg/km
  • Permissible current rating in open air: 36 A

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-353; IEC 60092-360
  • Test
    IEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

MPRX®331 0.6/1 kV fire resistant power and control cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. They are used for detection and warning systems not subject to mechanical risks.

The highly flexible MPRX®331 FLEXISHIP® range is recommended for installations and connections in narrow spaces where an optimal bending radius is required. The sectoral conductors of multicores cables provide further space and weight savings on the cable trays. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

1.    Conductor:
       Stranded bare copper, class 2 or class 5 for FLEXISHIP®

2.    Insulation
       
Mica tape + XLPE (cross-linked polyethylene)
       Optional: Special fire resistant HF 90 (halogen-free compound)
       with INFITTM  technology up to 4 mm²

3.    Outer sheath:
       (Filler if necessary)
       Polyolefin SHF1 (SHF2 on request)
       Colour: orange

Marking

I NEXANS I MPRX 331  or MPRX 331 FLEXISHIP 0.6/1 kV  "n" x (orG) "s"  90°C IEC 60092-353 IEC 60332-3-22 Cat. A IEC 60331-1/21 "ww/yy" * CE*

+ metric marking

 

 

 

Core Identification

1 core:   black

2 cores: brown-blue

3 x:        brown-black-grey

3G:        brown-blue-green/yellow

4 x:        brown-black-grey-blue

4G:        brown-black-grey-green/yellow

> 5 cores: n x: white with printed numbers / nG: white with printed numbers + green/yellow core

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Sheath colour
Orange
With Green/Yellow core
No

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Fire resistant
IEC 60331-21, IEC 60331-1 or 2
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.